Changes between Version 1 and Version 2 of q3302ew


Ignore:
Timestamp:
04/08/12 17:38:48 (9 years ago)
Author:
branden
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • q3302ew

    v1 v2  
    55 
    66== Function == 
    7 A Quanterra Q330 data feeding program, rewritten by ISTI using Lib330 from Quanterra (not MountainAir). 
     7A Quanterra Q330 data feeding program, rewritten by ISTI using Lib330 from Quanterra (not !MountainAir). 
    88 
    99 
     
    168168}}} 
    169169 
    170 '''!Dutycycle_BufferLevel [pcnt]''' 
    171  
    172 When the Q330's buffer level is down to pcnt percent filled, disconnect and wait for the number of minutes configured in !Dutycycle_SleepTime before reconnecting and drawing the buffer back down to pcnt again. 
     170'''Dutycycle_BufferLevel [pcnt]''' 
     171 
     172When the Q330's buffer level is down to pcnt percent filled, disconnect and wait for the number of minutes configured in Dutycycle_SleepTime before reconnecting and drawing the buffer back down to pcnt again. 
    173173 
    174174Comment out to disable. 
     
    178178}}} 
    179179   
    180 '''!Dutycycle_MaxConnectTime [minutes]''' 
    181  
    182 After retrieving data from the Q330 for this many minutes, disconnect and wait the number of minutes configured in !Dutycycle_SleepTime before reconnecting for and retrieving data from the Q330 for this many minutes again. 
     180'''Dutycycle_MaxConnectTime [minutes]''' 
     181 
     182After retrieving data from the Q330 for this many minutes, disconnect and wait the number of minutes configured in Dutycycle_SleepTime before reconnecting for and retrieving data from the Q330 for this many minutes again. 
    183183 
    184184Comment out to disable. 
     
    188188}}} 
    189189 
    190 '''!Dutycycle_SleepTime [minutes]''' 
    191  
    192 When data acquisition has been stopped as a result of !Dutycycle_MaxConnectTime or !Dutycycle_BufferLevel, sleep this many minutes before reconnecting again. 
     190'''Dutycycle_SleepTime [minutes]''' 
     191 
     192When data acquisition has been stopped as a result of Dutycycle_MaxConnectTime or Dutycycle_BufferLevel, sleep this many minutes before reconnecting again. 
    193193 
    194194Comment out to disable. 
     
    211211 
    212212'''IPAddress [addr]''' 
    213                                          
     213 
    214214This is the IP address of the Q330 to be accessed. On most systems, this may be a hostname as well. 
    215215{{{ 
     
    289289}}} 
    290290 
    291 !StatusInterval [secs] 
     291'''!StatusInterval [secs]''' 
    292292 
    293293This is the frequency, in seconds, to display status checkpoints in the logfile